S8FS-C03505 Switch Mode Power Supply ,35W , 5VDC , Model with terminal block facing upward

OmronSKU: S8FS-C03505
No reviews

Output voltage: S8FS-C03505
Price:
Sale price0.00 ฿

Shipping calculated at checkout

Stock:
Re-stocking soon

Description

Features

S8FS-C03505 :

  • Power rating : 35 W
  • Output voltage (VDC) : 5 V
  • Input :
  • Efficiency : 115 VAC input (81% typ.) , 230 VAC input (81% typ.)
  • Voltage range :Single phase 85 to 264 VAC, 120 to 370 VDC (The L terminal for the DC input is the positive side and safety standards do not apply.) 
  • Frequency : 50 /60 Hz (47 to 450 Hz)
  • Current : 115 VAC input 0.66 A typ. , 230 VAC input 0.41 A typ.
  • Leakage current : 115 VAC input (0.15 mA) , 230 VAC input  (0.30 mA)
  • Inrush current (for a cold start at 25°) : 115 VAC input 16 A typ.
    ,230 VAC input 32 A typ.
  • Output :
  • Rated Output Current : 7 A
  • Voltage adjustment range : −10% to 10% (with V. ADJ)
  • Ripple & Noise voltage (100 to 240 VAC input) : 80 mVp-p max.
  • Input variation influence : 0.5% max
  • Load variation influence : 1.0% max.
  • Temperature variation influence (100 to 240 VAC input) : 0.03%/°C max
  • Startup time (115 VAC input) 750 ms typ. , (230 VAC input) 700 ms typ
  • Hold time : (115 VAC input) 13 ms typ. , (230 VAC input) 74 ms typ
    Overvoltage protection : Yes, 115% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again)

S8FS-C03512 :

  •  Power rating : 35 W
  • Output voltage (VDC) : 12 V
  • Input :
  • Efficiency : 115 VAC input (83% typ.) , 230 VAC input (84% typ.)
  • Voltage range :Single phase 85 to 264 VAC, 120 to 370 VDC (The L terminal for the DC input is the positive side and safety standards do not apply.) (Derating is required according to the input voltage. Refer to Derating Curves on page 18.)
  • Frequency : 50 /60 Hz (47 to 450 Hz)
  • Current : 115 VAC input 0.66 A typ. , 230 VAC input 0.41 A typ.
  • Leakage current : 115 VAC input (0.15 mA) , 230 VAC input (0.25 mA)
  • Inrush current (for a cold start at 25°) : 115 VAC input 16 A typ.
    ,230 VAC input 32 A typ.
  • Output :
  • Rated Output Current : 3 A
  • Voltage adjustment range : −10% to 10% (with V. ADJ)
  • Ripple & Noise voltage (100 to 240 VAC input) : 90 mVp-p max.
  • Input variation influence : 0.5% max
  • Load variation influence : 1.0% max.
  • Temperature variation influence (100 to 240 VAC input) : 0.03%/°C max
  • Startup time (115 VAC input) 750 ms typ. , (230 VAC input) 690 ms typ
  • Hold time : (115 VAC input) 14 ms typ. , (230 VAC input) 75 ms typ
    Overvoltage protection : Yes, 115% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again)

S8FS-C03515 :

  •  Power rating : 35 W
  • Output voltage (VDC) : 15 V
  • Input :
  • Efficiency : 115 VAC input (84% typ.) , 230 VAC input (84% typ.)
  • Voltage range :Single phase 85 to 264 VAC, 120 to 370 VDC (The L terminal for the DC input is the positive side and safety standards do not apply.) (Derating is required according to the input voltage. Refer to Derating Curves on page 18.)
  • Frequency : 50 /60 Hz (47 to 450 Hz)
  • Current : 115 VAC input 0.66 A typ. , 230 VAC input 0.41 A typ.
  • Leakage current : 115 VAC input (0.15 mA) , 230 VAC input (0.25 mA)
  • Inrush current (for a cold start at 25°) : 115 VAC input 16 A typ.
    ,230 VAC input 32 A typ.
  • Output :
  • Rated Output Current : 2.4 A
  • Voltage adjustment range : −10% to 10% (with V. ADJ)
  • Ripple & Noise voltage (100 to 240 VAC input) : 90 mVp-p max.
  • Input variation influence : 0.5% max
  • Load variation influence : 1.0% max.
  • Temperature variation influence (100 to 240 VAC input) : 0.03%/°C max
  • Startup time (115 VAC input) 760 ms typ. , (230 VAC input) 710 ms typ
  • Hold time : (115 VAC input) 14 ms typ. , (230 VAC input) 75 ms typ
  • Overvoltage protection : Yes, 115% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again)

S8FS-C03524 :

  • Power rating : 35 W
  • Output voltage (VDC) : 24 V
  • Input :
  • Efficiency : 115 VAC input (87% typ.) , 230 VAC input (87% typ.)
  • Voltage range :Single phase 85 to 264 VAC, 120 to 370 VDC (The L terminal for the DC input is the positive side and safety standards do not apply.) (Derating is required according to the input voltage. Refer to Derating Curves on page 18.)
  • Frequency : 50 /60 Hz (47 to 450 Hz)
  • Current : 115 VAC input 0.66 A typ. , 230 VAC input 0.41 A typ.
  • Leakage current : 115 VAC input (0.15 mA) , 230 VAC input (0.25 mA)
  • Inrush current (for a cold start at 25°) : 115 VAC input 16 A typ.
    ,230 VAC input 32 A typ.
  • Output :
  • Rated Output Current : 1.5 A
  • Voltage adjustment range : −10% to 10% (with V. ADJ)
  • Ripple & Noise voltage (100 to 240 VAC input) : 80 mVp-p max.
  • Input variation influence : 0.5% max
  • Load variation influence : 1.0% max.
  • Temperature variation influence (100 to 240 VAC input) : 0.03%/°C max
  • Startup time (115 VAC input) 770 ms typ. , (230 VAC input) 720 ms typ
  • Hold time : (115 VAC input) 15 ms typ. , (230 VAC input) 79 ms typ
  • Overvoltage protection : Yes, 115% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again)

Term and Condition

รับประกันสินค้า : 1 Year

Download

Datasheet
Download

ดูล่าสุด